Surge & Lightning Protection

Complete Surge Protection Solutions
PROBLOC BSR 100/275 (4+0)

The PROBLOC BS(R) 100 (4+0) series of over voltage surge protective devices has been developed to protect against
partial direct and indirect lightning discharges and is intended to provide protection in zones 0A - 1 as per IEC 62305.

  • Category IEC / EN / VDE: Class I / Type 1 / B+C
  • Use for Main distribution boards
  • High energy MOV and GDT
  • Iimp = 12.5kA / pole, Imax = 50kA / pole
  • Mechanical flag + remote contacts (R)
  • Protec CR 80/275 (2+0)

    The PROTEC CR 80 (2+0) series of low cost, over voltage surge protective devices has been developed to protect
    against indirect lightning discharges and is intended to provide protection in zones 1 - 2 as per IEC 62305.

  • Category IEC / EN / VDE: Class II / Type 2 / C
  • Use for Branch sub-distribution boards
  • MOV protective element
  • In = 15kA , Imax = 40kA
  • Mechanical flag + remote contacts (R)
  • Protec CR 80/275 (1+1)

    The PROTEC CR 80 (1+1) series of low cost, over voltage surge protective devices has been developed to protect
    against indirect lightning discharges and are intended to provide protection in zones 1 - 2 as per IEC 62305.

  • Category IEC / EN / VDE: Class II / Type 2 / C
  • Use for Branch sub-distribution boards
  • MOV and GDT element
  • In = 15kA , Imax = 40kA
  • Mechanical flag + remote contacts (R)
  • NMH2-TC (2 Signal Protector)

    The NMH2-TC series that can provide protection to two independent of low voltage protective devices has been developed to
    protect against the effects of induced voltages onto data, signal and communication circuits.

  • Use for 2-pair SPD
  • RS485, CAN, RS232, 4-20 mA, D/I, D/O, leased line 3 stage protector
  • Coarse and Fine Protection
  • In = 10kA , Imax = 20kA
  • IMH-TC (Signal Protector)

    The IMH-TC series of low voltage protective devices has been developed to protect against the effects of induced voltages
    onto data, signal and communication circuits.

  • RS485, CAN, RS232, 4-20 mA, D/I, D/O, leased line 3 stage protector
  • Use for Single-pair SPD
  • Coarse and Fine Protection
  • In = 10kA , Imax = 20kA
  • VM-DC (Supply Line Protector)

    The VM-DC series has been developed to protect DC power supplies.

  • Nominal Operating Voltage: 12VDC / 24 VDC
  • Use for SPD for DC Power Supplies
  • Coarse and Fine Protection
  • In = 10kA , Imax = 20kA
  • LZ-NET6 (LAN Protector)

    The LZ-NET6 series is intended to protect Local AreaNetworks (LAN) from over voltage surges and electrostatic
    discharges created by switching transients in buildings.

  • LAN Protector (1 way)
  • Compact, Ergonomic Packaging
  • Termination: RJ45, Cat. 6 Capable
  • In: 150 A 8/20 per line
  • LZ-NET (RJ-45 LAN Protector)

    The LZ-NET series is intended to protect Local AreaNetworks (LAN) from over voltage surges and electrostatic
    discharges created by switching transients in buildings.

  • LAN Protector (1 way)
  • Compact, Ergonomic Packaging
  • Termination: RJ45, Cat. 5 Connectors
  • In: 300 A 8/20 per line
  • ZV-BNC (Coaxial Video Surge Protector)

    The ZV-BNC series is intended to protect Arcnet computer networks and CCTV coaxial video signals.

  • Coaxial BNC Protector
  • For CCTV and Arcnet
  • Indirect Shield Earthing
  • In = 10kA, IL = 100mA
  • For other modules please see below complete catalogs.

    Low Voltage Power Supply System 2014

    Protective Devices for Data Control System 2014

    Protective Devices for Wind Systems 2015                      *** NEW MANUAL ***

    Protective Devices for Photovoltaic Systems 2015         *** NEW MANUAL***

    Key reference installations:
    Customer Location Application
    Thailand
    MWA Metropolitan Waterworks Authority, Bangkok Freshwater Utility for Bangkok
    MEA Metropolitan Electricity Authority, Bangkok Electricity Utility
    PWA Provincial Waterworks Authority, Thailand Freshwater Utility for all of Thailand except Bangkok
    PEA Provincial Electricity Authority, Thailand Electricity Utility for all of Thailand except Bangkok
    RID Royal Irrigation Department, Thailand Water distribution for farmland
    WRD Thailand Water resources department
    BMA Bangkok Bangkok Metropolitan Administration
    PTT Petroleum AuThority of Thailand Gas Supplier for Thailand
    Major System Integrators:
    Customer
    Thailand
    Omron
    ABB
    Schneider



    PLC, HMI, Servo Drive & Remote I/O
    SCADA Software
    Flow Computers and software integration
    Industrial Data Communication
    Industrial Switching Power Supply, DC-DC Converter
    Surge & Lightning Protection
    GSM/GPRS Modem
    1+ Power Switching Power Supply
    1+ Power Switching Power Supply
    © Industrial Technology Supply Co., Ltd. All rights reserved.                                   Number of Visitors: Advanced Web Counter